- Heat Pump Water Heaters[6]
- Dehumidifiers[6]
- Other Home Appliances[3]
- Other Electrical Equipment[6]
- Air Conditioners[6]
- Industrial Air Conditioners[2]
- HVAC Systems & Parts[5]
- Heat Pump Water Heater Parts[6]
- Refrigeration & Heat Exchange Parts[1]
- Industrial Chiller[1]
- Floor Heating Systems & Parts[6]
- Other Home Heaters[2]
- Air Conditioner Parts[6]
- Fans[1]
- Fan Parts[2]
- Solar Water Heater Parts[5]
- Electric Water Heater Parts[6]
- Energy Projects[1]
- Exhibiting Services[6]
- Other Project Cooperation[3]
- Industrial Supplies Projects[1]
- Contact Person : Mr. Zhang Junji
- Company Name : Foshan Macon Cooling & Heating Energy-Saving Equipment Co., Ltd.
- Tel : 86-0757-23669556
- Fax : 86-0757-23669554
- Address : Guangdong,Foshan,No.12,Fuan 1st Industrial Area,Leliu Town,Shunde District
- Country/Region : China
- Zip : 528322
Related Product Searches:Industrial heat pump water heater air to water,High Quality,Industral heat pump, water heater,MAHRW060ZB/(P)S
Air to water heat pump water heater
Model 1 | MAHRW | 030ZB/(P) | 040ZB/(P) | 050ZB/(P)S | 060ZB/(P)S |
Model 2 | MAHRW | 030ZB/(P)(E) | 040ZB/(P)(E) | 050ZB/(P)S(E) | 060ZB/(P)S(E) |
Rated Output Water | L/h | 225 | 300 | 375 | 450 |
Heating Capacity(1) | kW | 10.5 | 14.0 | 17.5 | 21.0 |
BTU/h | 35900 | 47800 | 59800 | 71700 | |
COP(1) | W/W | 3.6 | 3.6 | 3.6 | 3.6 |
Input Power(1) | kW | 2.92 | 3.89 | 4.86 | 5.83 |
Input Current(1) | A | 13.3 | 17.7 | 7.4 | 8.9 |
Heating Capacity(2) | kW | 9.0 | 12.0 | 15.0 | 18.0 |
BTU/h | 30800 | 41000 | 51200 | 61500 | |
COP(2) | W/W | 3.26 | 3.26 | 3.26 | 3.26 |
Input Power(2) | kW | 2.76 | 3.68 | 4.60 | 5.52 |
Input Current(2) | A | 12.5 | 16.7 | 7.0 | 8.4 |
Heating Capacity(3) | kW | 9.6 | 12.8 | 16.0 | 19.2 |
BTU/h | 32800 | 43700 | 54600 | 65600 | |
COP(3) | W/W | 4.12 | 4.12 | 4.12 | 4.12 |
Input Power(3) | kW | 2.33 | 3.11 | 3.88 | 4.66 |
Input Current(3) | A | 10.6 | 14.1 | 5.9 | 7.1 |
Rated Temp.Of Water Output | °C | 55 | |||
Power Supply | V/PH/Hz | 220/1/50 | 220/1/50 | 380/3/50 | 380/3/50 |
Noise | dB(A) | 52 | 54 | 54 | 55 |
Compressor | Scroll | Scroll | Scroll | Scroll | |
Compressor Qty | 1 | 1 | 1 | 1 | |
Fan Qty | 1 | 1 | 1 | 1 | |
Fan Direction | vertical | vertical | vertical | vertical | |
Water Flow Volume | m3/h | 2 | 2.5 | 3 | 3.5 |
Water Out let/Water In let | inch | 1 | 1 | 1 | 1 |
Refrigerant Type | R410A/R407C/R134a | ||||
Unit Net Dimensions ( L/M/H ) | mm | 760/704/770 | 860806/970 | 860/806/970 | 860/806/970 |
Unit Shipping Dimensions ( L/M/H ) | mm | 785/770/870 | 890/870/1070 | 890/870/1070 | 890/870/1070 |
Net Weight | kg | 80 | 95 | 115 | 120 |
Shipping Weight | kg | 95 | 110 | 130 | 135 |
Note:(1)Heating:Outdoor air temp:20°C/15°C,water tank water temperature from15°C heating to 55°C;(2)Heating:Outdoor air temp:7°C/6°C,Outlet water temp:45°C,Input water temp:40°C;(3)Heating:Outdoor air temp:7°C/6°C,Outlet water temp:35°C,Input water temp:30°C;(4)Model 1 Using in ambient temperature:-15°C~43°C;(4)Model 2 (EVI Technology) Using in ambient temperature:-25°C~43°C. |
Wide application
The modular structure is the best choice and suitable for various sizes of engineering, office buildings, hotels, restaurants, cinema, shopping plaza, gymnasium, various public hospital ect.
Multistage energy regulation
According to different load flexible use of multistage energy regulation.
High efficiency and energy saving
Using high-efficient compressor rotary or scroll and heat exchanger, small volume,strong heat enchange capacity, up 10% than the same old units.
Multi-protect and reliable
Unit protection against freezing, compressor high-pressure compressor, high and low voltage protection, compressor overtemperature, compressors flow, power supply phase sequence,ensure unit works in hash environment.
Optional for integral type and split type, and easy to installation
Built in WILO pumps, flow switches, easy to install pipe connections, especially in split type design, take water system entirely in indoor, completely solved the problem of the water system freezing in cold weather,, particularly suitable for cold areas.
Air to Water Heat Pump
It is EVI design for 60oC higher water temperature, especially for the extremely cold area, like -25oC ambient temperature; Its core philosophy is to solve the house heating during the cold climate in Winter and Spring and make room cooling in hot Summer and Autumn. This kind of design can do not only heating and cooling but also can provide sanitary hot water all over the year because the second circle heating can use 60oC hot water to heat the 10~15 oC tap water to 55 ~60 oC sanitary water. So it is realized to offer heating,cooling and sanitary hot water with only one heat pump.
The heat pump performance has been improved greatly with Copeland new designed EVI compressor from the United States Emerson Ltd and with MACON specially designed economizer and high efficiency heat transfer module.With six months of performance testing and validation in the different conditions of Multifunctions Lab.,the EVI Series Heat Pump has reached the COP=4.2 for floor heating mode (EN14511-2007) and it is available for 60 oC hot water output and safely working in -25 oC ambient temperature.
1. Higher Water Temperature Output up to 60oC2. Safely Working Temperature Down to: -25oC
3. High Efficiency COP up to 4.2 (EN14511-2007)
4. Three in One : Heating, Cooling and Sanitary Hot Water